80 research outputs found

    Trends in microfluidic systems for in situ chemical analysis of natural waters

    Get PDF
    Spatially and temporally detailed measurement of ocean, river and lake chemistry is key to fully understanding the biogeochemical processes at work within them. To obtain these valuable data, miniaturised in situ chemical analysers have recently become an attractive alternative to traditional manual sampling, with microfluidic technology at the forefront of recent advances. In this short critical review we discuss the role, operation and application of in situ microfluidic analysers to measure biogeochemical parameters in natural waters. We describe recent technical developments, most notably how pumping technology has evolved to allow long-term deployments, and describe how they have been deployed in real-world situations to yield detailed, scientifically useful data. Finally, we discuss the technical challenges that still remain and the key obstacles that must be negotiated if these promising systems are to be widely adopted and used, for example, in large environmental sensor networks and on low-power underwater vehicles

    A novel portable filtration system for sampling and concentration of microorganisms: Demonstration on marine microalgae with subsequent quantification using IC-NASBA

    Get PDF
    This paper presents a novel portable sample filtration/concentration system, designed for use on samples of microorganisms with very low cell concentrations and large volumes, such as water-borne parasites, pathogens associated with faecal matter, or toxic phytoplankton. The example application used for demonstration was the in-field collection and concentration of microalgae from seawater samples. This type of organism is responsible for Harmful Algal Blooms (HABs), an example of which is commonly referred to as “red tides”, which are typically the result of rapid proliferation and high biomass accumulation of harmful microalgal species in the water column or at the sea surface. For instance, Karenia brevis red tides are the cause of aquatic organism mortality and persistent blooms may cause widespread die-offs of populations of other organisms including vertebrates. In order to respond to, and adequately manage HABs, monitoring of toxic microalgae is required and large-volume sample concentrators would be a useful tool for in situ monitoring of HABs. The filtering system presented in this work enables consistent sample collection and concentration from 1 L to 1 mL in five minutes, allowing for subsequent benchtop sample extraction and analysis using molecular methods such as NASBA and IC-NASBA. The microalga Tetraselmis suecica was successfully detected at concentrations ranging from 2 × 105 cells/L to 20 cells/L. Karenia brevis was also detected and quantified at concentrations between 10 cells/L and 106 cells/L. Further analysis showed that the filter system, which concentrates cells from very large volumes with consequently more reliable sampling, produced samples that were more consistent than the independent non-filtered samples (benchtop controls), with a logarithmic dependency on increasing cell numbers. This filtering system provides simple, rapid, and consistent sample collection and concentration for further analysis, and could be applied to a wide range of different samples and target organisms in situations lacking laboratories

    Developments in marine pCO2 measurement technology; towards sustained in situ observations

    Get PDF
    The oceanic uptake of anthropogenic CO2 causes pronounced changes to the marine carbonate system. High quality pCO2 measurements with good temporal and spatial coverage are required to monitor the oceanic uptake, identify regions with pronounced carbonate system changes, and observe the effectiveness of CO2 emission mitigation strategies. There are currently several instruments available, but many are unsuitable for autonomous deployments on in situ platforms such as gliders, moorings and Argo floats. We assess currently available technology on its suitability for in situ deployment, with a focus on optode technology developments. Optodes for pCO2 measurements provide a promising new technological approach, and were successfully calibrated over the range of 280–480 μatm applying modified time-domain dual lifetime referencing. A laboratory precision of 0.8 μatm (n = 10) and a response time (τ90) of 165 s were achieved, and with further development pCO2 optodes may become as widely used as their oxygen counterparts

    Nitrate and nitrite variability at the seafloor of an oxygen minimum zone revealed by a novel microfluidic in-situ chemical sensor

    Get PDF
    Microfluidics, or lab-on-a-chip (LOC) is a promising technology that allows the development of miniaturized chemical sensors. In contrast to the surging interest in biomedical sciences, the utilization of LOC sensors in aquatic sciences is still in infancy but a wider use of such sensors could mitigate the undersampling problem of ocean biogeochemical processes. Here we describe the first underwater test of a novel LOC sensor to obtain in situ calibrated time-series (up to 40 h) of nitrate+nitrite (ΣNOx) and nitrite on the seafloor of the Mauritanian oxygen minimum zone, offshore Western Africa. Initial tests showed that the sensor successfully reproduced water column (160 m) nutrient profiles. Lander deployments at 50, 100 and 170 m depth indicated that the biogeochemical variability was high over the Mauritanian shelf: The 50 m site had the lowest ΣNOx concentration, with 15.2 to 23.4 μM (median=18.3 μM); while at the 100 site ΣNOx varied between 21.0 and 30.1 μM over 40 hours (median = 25.1μM). The 170 m site had the highest median ΣNOx level (25.8 μM) with less variability (22.8 to 27.7 μM). At the 50 m site, nitrite concentration decreased fivefold from 1 to 0.2 μM in just 30 hours accompanied by decreasing oxygen and increasing nitrate concentrations. Taken together with the time series of oxygen, temperature, pressure and current velocities, we propose that the episodic intrusion of deeper waters via cross-shelf transport leads to intrusion of nitrate-rich, but oxygen-poor waters to shallower locations, with consequences for benthic nitrogen cycling. This first validation of an LOC sensor at elevated water depths revealed that when deployed for longer periods and as a part of a sensor network, LOC technology has the potential to contribute to the understanding of the benthic biogeochemical dynamics

    Characterization of a Time-Domain Dual Lifetime Referencing pCO2 Optode and Deployment as a High-Resolution Underway Sensor across the High Latitude North Atlantic Ocean

    Get PDF
    The ocean is a major sink for anthropogenic carbon dioxide (CO2), with the CO2 uptake causing changes to ocean chemistry. To monitor these changes and provide a chemical background for biological and biogeochemical studies, high quality partial pressure of CO2 (pCO2) sensors are required, with suitable accuracy and precision for ocean measurements. Optodes have the potential to measure in situ pCO2 without the need for wet chemicals or bulky gas equilibration chambers that are typically used in pCO2 systems. However, optodes are still in an early developmental stage compared to more established equilibrator-based pCO2 systems. In this study, we performed a laboratory-based characterization of a time-domain dual lifetime referencing pCO2 optode system. The pCO2 optode spot was illuminated with low intensity light (0.2mA, 0.72 mW) to minimize spot photobleaching. The spot was calibrated using an experimental gas calibration rig prior to deployment, with a determined response time (t63) of 50 s at 25◦C. The pCO2 optode was deployed as an autonomous shipboard underway system across the high latitude North Atlantic Ocean with a resolution of ca.10 measurements per hour. The optode data was validated with a secondary shipboard equilibrator-based infrared pCO2 instrument, and pCO2 calculated fromdiscrete samples of dissolved inorganic carbon and total alkalinity. Further verification of the pCO2 optode data was achieved using complimentary variables such as nutrients and dissolved oxygen. The shipboard precision of the pCO2 sensor was 9.5μatmdetermined both from repeat measurements of certified reference materials and from the standard deviation of seawater measurements while on station. Finally, the optode deployment data was used to evaluate the physical and biogeochemical controls on pCO2

    Early warning device for detection of pollutants in water

    Get PDF
    Due to a growing need to protect water resources from contamination, there is a requirement for the development of more reliable and cost effective devices for water quality monitoring. The aim of the AQUAWARN project is to develop and deploy a fully autonomous water quality monitoring device that can measure nitrite, nitrate, phosphate and pH colorimetrically in fresh water and wastewater, and communicate the information to stakeholders in real time

    Early warning pollution detection device for application in water quality

    Get PDF
    It has been well recognised that water is a valuable resource and the quality of our water systems require sampling at a higher temporal and spatial frequency than is currently taking place. The AQUAWARN project aims to meet this challenge through the development of commercially competitive water quality monitoring devices. These will be capable of performing analytical measurements in situ - primarily aimed at freshwater and wastewater systems. The analytes of interest are mainly phosphate, nitrite, nitrate, and pH. The initial focus of this project is the assessment and optimisation of appropriate colorimetric chemistries for each sensing target. These chemistries have been developed and optimised using bench-top instrumentation. Integration within microfluidic chips followed to reduce the per sample costs. Microfluidic technology uses minute amounts of reagent per sample measurement, allowing for a dramatic increase in the number of potential assays per unit volume of reagent. Moreover, the integration of LEDs and photodiodes as light sources and detectors, coupled with syringe pumps, opens the way to new generations of low-cost, portable, and autonomous devices, capable of performing multiple in-situ measurements.  For example, an analysis requiring 50 uL of reagent implies 2,000 measurements are possible per 100 mL of reagent

    Characterization of meta-Cresol Purple for spectrophotometric pH measurements in saline and hypersaline media at sub-zero temperatures

    Get PDF
    Accurate pH measurements in polar waters and sea ice brines require pH indicator dyes characterized at near-zero and below-zero temperatures and high salinities. We present experimentally determined physical and chemical characteristics of purified meta-Cresol Purple (mCP) pH indicator dye suitable for pH measurements in seawater and conservative seawater-derived brines at salinities (S) between 35 and 100 and temperatures (T) between their freezing point and 298.15 K (25 °C). Within this temperature and salinity range, using purified mCP and a novel thermostated spectrophotometric device, the pH on the total scale (pHT) can be calculated from direct measurements of the absorbance ratio R of the dye in natural samples as pHT=−log(kT2e2)+log(R−e11−Re3e2) Based on the mCP characterization in these extended conditions, the temperature and salinity dependence of the molar absorptivity ratios and − log(kT2e2) of purified mCP is described by the following functions: e1 = −0.004363 + 3.598 × 10−5T, e3/e2 = −0.016224 + 2.42851 × 10−4T + 5.05663 × 10−5(S − 35), and − log(kT2e2) = −319.8369 + 0.688159 S −0.00018374 S2 + (10508.724 − 32.9599 S + 0.059082S2) T−1 + (55.54253 − 0.101639 S) ln T −0.08112151T. This work takes the characterisation of mCP beyond the currently available ranges of 278.15 K ≤ T ≤ 308.15 K and 20 ≤ S ≤ 40 in natural seawater, thereby allowing high quality pHT measurements in polar systems

    A highly specific Escherichia coli qPCR and its comparison with existing methods for environmental waters

    Get PDF
    The presence of Escherichia coli in environmental waters is considered as evidence of faecal contamination and is therefore commonly used as an indicator in both water quality and food safety analysis. The long period of time between sample collection and obtaining results from existing culture based methods means that contamination events may already impact public health by the time they are detected. The adoption of molecular based methods for E. coli could significantly reduce the time to detection. A new quantitative real-time PCR (qPCR) assay was developed to detect the ybbW gene sequence, which was found to be 100% exclusive and inclusive (specific and sensitive) for E. coli and directly compared for its ability to quantify E. coli in environmental waters against colony counts, quantitative real-time NASBA (qNASBA) targeting clpB and qPCR targeting uidA. Of the 87 E. coli strains tested, 100% were found to be ybbW positive, 94.2% were culture positive, 100% were clpB positive and 98.9% were uidA positive. The qPCR assays had a linear range of quantification over several orders of magnitude, and had high amplification efficiencies when using single isolates as a template. This compared favourably with qNASBA which showed poor linearity and amplification efficiency. When the assays were applied to environmental water samples, qNASBA was unable to reliably quantify E. coli while both qPCR assays were capable of predicting E. coli concentrations in environmental waters. This study highlights the inability of qNASBA targeting mRNA to quantify E. coli in environmental waters, and presents the first E. coli qPCR assay with 100% target exclusivity. The application of a highly exclusive and inclusive qPCR assay has the potential to allow water quality managers to reliably and rapidly detect and quantify E. coli and therefore take appropriate measures to reduce the risk to public health posed by faecal contamination